Brand Name : Rexroth
Model Number : 4WRA6EB20-1X/24NK4/M 4WRA6EA05-1X/24K4/M 4WRA6E1-07-2X/G24K4/V 4WRA6EB15-2X/G24K4/V 4WRA6EA07-2X/G24K4/V
Certification : ISO
Place of Origin : German
MOQ : 1
Price : 2
Payment Terms : MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability : 100
Delivery Time : 2 weeks
Packaging Details : wooden box
Direction Of Rotation : Clockwise or Counterclockwise
Mounting Type : Flange or Foot Mounting
Charging : micro5p
Type : Axial Piston Pump
Control Type : Pressure Compensator
Drive Mode : 6-250m3
Rotation : Clockwise or Counterclockwise
Speed : Hydraulic oil, water ethylene glycol
Shaft Type : Splined or Tapered
Fuel : Gasoline
4WRA6EB20-1X/24NK4/M
4WRA6EA05-1X/24K4/M
4WRA6E1-07-2X/G24K4/V
4WRA6EB15-2X/G24K4/V
4WRA6EA07-2X/G24K4/V Rexroth proportional directional valve, German original imported hydraulic valve
| Processing & Customization | yes | type | proportional valve |
| material | cast steel | model | 4WRA6EB20-1X/24NK4/M 4WRA6EA05-1X/24K4/M 4WRA6E1-07-2X/G24K4/V 4WRA6EB15-2X/G24K4/V 4WRA6EA07-2X/G24K4/V |
| brand | REXROTH | Scope of Application | hydraulic system |
| Product Alias | Proportional directional valve | Applicable Medium | oil products |
| Applicable Temperature | Normal temperature (℃) ℃ | Nominal Pressure | Normal pressure (MPa) MPa |
| Nominal Diameter | 6-way diameter (mm) mm | Installation type | Threaded installation |
| Operating Temperature | room temperature | Type (channel location) | Straight through type |

| 4WRA6W10-1X/24NJ/M |
| 4WRA6W20-1X/24NJ/M |
| 4WRA6W10-1X/24NZ4/V |
| 4WRA6W20-1X/24N9Z4/M |
| 4WRA6WA20-1X/24Z4/M |
| 4WRA6W05-1X/24N9Z4/M |
| 4WRA6WB05-1X/24NZ4/M |
| 4WRA6W20-1X/24NJ/V |
| 4WRA6W20-1X/24Z4/V |
| 4WRA6W10-1X/24N9Z4/M |
| 4WRA6WB10-1X/24NZ4/M |
| 4WRA6W05-1X/24N9Z4/V |
| 4WRA6WB10-1X/24Z4/M |
| 4WRA6W10-1X/24NK4/M |
| 4WRA6W05-1X/24N9K4/M |
| 4WRA6W20-1X/24K4/M |
| 4WRA6W05-1X/24NK4/M |
| 4WRA6W2-20-1X/24NZ4/M |
| 4WRA6W20-1X/24NZ4/V |
| 4WRA6W10-1X/24Z4/V |
| 4WRA6W1-20-1X/24N9Z4/M |
| 4WRA6W10-1X/24Z4/M |
| 4WRA6W20-1X/24Z4/M |
| 4WRA6W05-1X/24Z4/M |
| 4WRA6W1-20-1X/24Z4/M |
| 4WRA6W1-05-1X/24NZ4/M |
| 4WRA6W1-10-1X/24NZ4/M |
| 4WRA6WA20-1X/24N9K4/M |
| 4WRA6W20-1X/24N9Z4/V |
| 4WRA6W2-05-1X/24Z4/M |
| 4WRA6WB05-1X/24Z4/M |
| 4WRA6W1-05-1X/24Z4/M |
| 4WRA6W1-05-1X/24N9Z4/M |
| 4WRA6W10-1X/24NZ4/MR |
| 4WRA6W15-2X/G24N9Z4/V |
| 4WRA6W1-20-1X/24NZ4/MR |
| 4WRA6W10-1X/24K4/M |
| 4WRA6W20-1X/24N9K4/V |
| 4WRA6W10-1X/24N9K4/M |
| 4WRA6WA07-2X/G24K4/V |
| 4WRA6W07-2X/G24NJK31/V |
| 4WRA6W30-2X/G24N9Z4/V |
| 4WRA6W05-1X/24NZ4/MR |
| 4WRA6WA30-2X/G24Z4/V |
| 4WRA6W30-2X/G24N9K4/V |
| 4WRA6W20-1X/24NZ4/MR |
| 4WRA6W1-30-2X/G24N9K4/V |
| 4WRA6W1-10-1X/24NZ4/MR |
| 4WRA6W1-15-2X/G24N9Z4/V |
| 4WRA6W1-30-2X/G24N9Z4/V |
| 4WRA6W20-1X/12N9Z4/V |
| 4WRA6WA10-1X/24N9Z4/V |
| 4WRA6W15-2X/G24N9K4/V |
| 4WRA6WA15-2X/G24N9Z4/V |
| 4WRZ10W6A85-70/6EG24N9EK4/M |
| 4WRZ10W8-25-70/6EG24N9EK4/D3M |
| 4WRZ10W9-85-70/6EG24N9K4/M |
| 4WRZ10W9-50-70/6EG24N9EK4/M |
| 4WRZ10W9-50-70/6EG24N9K4/D3M |
| 4WRZ10W9-50-70/6EG24N9K4/M |
| 4WRZ10W9-25-70/6EG24N9EK4/M |
| 4WRZ10W9-25-70/6EG24N9K4/D3M |
| 4WRZ10W9-25-70/6EG24N9K4/M |
| 4WRZ10W8-85-70/6EG24N9EK4/M |
| 4WRZ10W8-85-70/6EG24N9K4/D3M |
| 4WRZ10W8-85-70/6EG24N9K4/M |
| 4WRZ10W8-50-70/6EG24N9EK4/M |
| 4WRZ10W8-50-70/6EG24N9K4/M |
| 4WRZ10W8-25-70/6EG24N9EK4/M |
| 4WRZ10W6A85-70/6EG24N9K4/D3M |
| 4WRZ10W8-25-70/6EG24N9K4/D3M |
| 4WRZ10W8-25-70/6EG24N9K4/M |
| 4WRZ10W6-85-70/6EG24N9TK4/D3M |
| 4WRZ10W6-85-70/6EG24N9ETK4/D3M |
| 4WRZ10W6-85-70/6EG24N9ETK4/M |
| 4WRZ10W8-50-70/6EG24N9K4/D3M |
| 4WRZ10EA25-70/6EG24N9K4/M |
| 4WRZ10EA50-70/6EG24N9K4/M |
| 4WRZ10EA85-70/6EG24N9K4/M |
| 4WRZ10W9-85-70/6EG24N9EK4/M |
| 4WRZ10W6A25-70/6EG24N9K4/D3M |
| 4WRZ10W6A50-70/6EG24N9K4/M |
FAQ:
What is the difference between 4WRA and 4WRAE?
The key difference lies in the location of the control electronics.
• 4WRA: Requires an external, separate amplifier to function. The amplifier processes the input signal (e.g., from a PLC) and provides the necessary power to the valve's solenoids .
• 4WRAE: Features Integrated OnBoard Electronics (OBE). The control electronics are built into the valve, allowing it to accept standard analog input signals (e.g., ±10 V or 4-20 mA) directly .
4. How do I read the model number? A typical 4WRA6 model code is structured as follows :
• 4WRA: Series designation for proportional directional valve without OBE. "E" after WRA (4WRAE) indicates integrated electronics.
• 6: Nominal size (06). Alternative size is 10.
• W / E / etc.: Spool symbol/type (e.g., W, E, EA), which defines the flow characteristics and center position condition .
• 07 / 15 / 30: Nominal flow rate in liters per minute at a pressure drop (Δp) of 10 bar. For size 06, common values are 7, 15, or 26/30 L/min .
• 2X: Component series (20-29).
• G24: Supply voltage (24 V DC).
• K4 / K31: Electrical connection type (e.g., without plug, with specific component socket) .
• V: Seal material (e.g., FKM for mineral oil) .
• A1 / F1 (for 4WRAE): Control value input type (A1 for ±10V, F1 for 4-20mA) .
5. What are the key technical specifications?
• Maximum Operating Pressure: Up to 350 bar for P, A, B ports .
• Maximum Flow: Varies with model (e.g., 42 L/min for some 4WRAE6 models) .
• Recommended Fluid Cleanliness: ISO 4406 20/18/15 .
• Voltage: Typically 24 V DC .
6. What are common applications for the 4WRA6 valve?
These valves are used in various industrial hydraulic systems requiring precise control, such as:
• Plastic injection molding machines .
• Presses and bending machines .
• Mobile equipment.
• Industrial automation systems where proportional control of speed and direction is needed.
7. What are common troubleshooting issues?
Common problems and their potential causes include :
• Valve does not shift or responds slowly: Check solenoid coil for burnout or open circuit; check power supply voltage; check for contamination causing the spool to stick.
• Internal Leakage: Worn spool or seals, or contamination causing improper sealing .
• Valve sticking: Often due to inadequate fluid cleanliness, insufficient lubrication, or internal damage .
• Excessive noise: Can be caused by excessive vibration, voltage fluctuations, or issues with the solenoid .
• No function despite signal: Check the amplifier (for 4WRA), wiring, and connections between the control unit and the valve .
8. What maintenance is required?
• Regularly check the solenoid coils and valve spool for wear .
• Maintain fluid cleanliness to prevent contamination, which is a primary cause of valve failure. Ensure the filtration system is functioning properly .
• Periodically inspect electrical connections and seals.
Note: For specific technical details, ordering information, or detailed troubleshooting for your application, always refer to the official REXROTH technical documentation or contact a certified supplier. The information provided here is for general reference based on public sources.
|
|
Rexroth Proportional Directional Valve with 1500-2700 RPM Rotation Speed ISO 4406 Fluid Cleanliness and 350 Bar Maximum Pressure Images |